• Français
  • English

Fire resistant boards

Geostaff fire resistant boards, mainly made of gypsum and fibreglass, are intended for passive fire protection and are tested according to EN 1366-1 and EN 1366-8.

Our fire-protective boards from the GEOTEC® and GEOFLAM® ranges allow you to create various passive fire protection solutions: horizontal and vertical ventilation and smoke extraction ducts; protections for service ducts; protection of bonded carbon reinforcements; protection of cable trays, for a fire exposure time of 1 to 3 hours.

GEOTEC® fire resistant boards can be joined using GEOCOL® glue and wood screws or by “polochons” or staples, whereas GEOFLAM® fire protective boards can only be joined using GEOCOL® glue and polochons*.

*Polochons: mixture of sisal fibre impregnated with plaster GEOPLASTRE®N

Products

Gypsum and fibreglass fire protective board for passive fire protection

GEOFLAM® F LIGHT boards

2-hr. fire protective board 35 mm thick and with dimensions from 200 to 1100 (W) x 1000 (L) mm (in steps of 50 mm).

Technical notice
Gypsum and fibreglass fire protective board for passive fire protection

GEOFLAM® FX50 boards

3-hr. fire protective board 50 mm thick and single dimension 1000 (W) x 900 (L) mm for passive fire protection.

Technical notice
Gypsum and fibreglass fire protective board for passive fire protection

GEOTEC® S30 boards

1 hr. fire protective board 30 mm thick and with dimensions from 200 to 1100 (W) x 1000 (L) mm (in steps of 50 mm).

Technical notice
Gypsum and fibreglass fire protective board for passive fire protection

GEOTEC® S45 boards

2-hr. fire protective board 45 mm thick and with dimensions from 200 to 1100 (W) x 1000 (L) mm (in steps of 50 mm).

Technical notice
Gypsum and fibreglass fire protective board for passive fire protection

GEOTEC® SX30 boards

1 hr. fire protective board, thickness 30 mm and unique dimension 1200 (W) x 1000 (L) mm.

Technical notice
Gypsum and fibreglass fire protective board for passive fire protection

GEOTEC® SX45 boards

2-hr. fire protective board 45 mm thick and unique dimension 1200 (W) x 1000 (L) mm for passive fire protection

Technical notice
Scroll to Top
Geostaff
Privacy Policy Summary

This site uses cookies so that we can provide you with the best possible user experience. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team understand which sections of the site you find most interesting and useful.