GEOTEC® and GEOFLAM® smoke extraction and ventilation ducts
Smoke extraction and ventilation :
When a fire breaks out inside a building, fire, smoke and heat are often confined indoors, creating an extremely dangerous environment for occupants. To control and manage these devastating effects, the installation of a smoke extraction and ventilation duct systems is essential. Indeed, the installation of ducts can be the key to protection that will delay the spread of smoke and save lives.
Current standards:
EN 1366-1 VENTILATION / 13501-3 / EIS
EN 1366-8 SMOKE EXTRACTION / 13501-4 / EIS Multi
GEOTEC® and GEOFLAM® smoke extraction and ventilation ducts
A key principle underpins the operation of fire-resistant ducts: a constant flow of air allows toxic fumes and hot gases to be rapidly extracted by fire-resistant smoke extraction ducts, while maintaining a supply of fresh air via fire-resistant ventilation ducts. This strategy limits smoke propagation, improves visibility for occupant evacuation and reduces temperature rise, thus contributing to better protection of people and infrastructure.
By complying with fire safety standards, these systems guarantee effective passive protection, essential for preventing and controlling fires in buildings.
Our GEOTEC® smoke extraction and ventilation ducts are a perfect example of this determination. We manufacture these systems by juxtaposing GEOTEC®S fire-resistant boards. Each board is 1000 mm wide (in 50 m increments) and is available in thicknesses of 30 or 45 mm.
All fire-resistant boards are molded to standard dimensions with a rebate on all four sides for 45 mm-thick ducts, and on two sides for 30 mm-thick ducts, to facilitate assembly.
GEOTEC® fire-resistant ducts can also be made using GEOTEC®SX fire-resistant boards with lengths of 1000 mm and widths of 1200 mm and thicknesses of 30 or 45 mm. These one-size-fits-all sheets have no longitudinal rabbets for easy cutting and assembly.
In addition to their use for smoke extraction and ventilation ducts, our GEOTEC® S fire-resistant boards also offer an effective solution for the protection of carbon fibre plates, as well as for the enclosure of technical ducts, thus guaranteeing enhanced fire safety in a variety of environments.

GEOFLAM® smoke extraction and ventilation ducts are another essential choice for fire protection.
These fire-resistant systems are designed by juxtaposing 35 mm-thick GEOFLAM® F-Light fire-resistant boards, which offer 2-hour fire resistance (EI120), or 50 mm-thick GEOFLAM® FX fire-resistant boards, which offer 3-hour fire resistance (EI180).
The installation of GEOFLAM® ventilation ducts is made easier by the use of the “polochonnage” method (a mixture of GEOPLASTER®, GEOCOL® glue and fiber sisal).
GEOFLAM® F- Light fire-resistant boards are molded to standard dimensions and are rebated on both sides to accommodate ducts.
Similarly, GEOFLAM® FX (100×90) fire-resistant boards are designed without longitudinal rabbets. This greatly facilitates cutting and assembly, which is advantageous for fire conduit installations.
GEOTEC® S range
Smoke extraction and ventilation | Laying method - glue + .... | Horizontal / Vertical | |
---|---|---|---|
Minimum cross-section (mm) | Maximum cross-section (mm) | ||
Screws | 50 x 50 | 2500 x 1500 | |
Staples | 1250 x 1000 | ||
Fiber sisal | 2500 x 2000 |
GEOFLAM® N range
Smoke extraction and ventilation | Laying method - glue + .... | Horizontal / Vertical | |
---|---|---|---|
Minimum cross-section (mm) | Minimum cross-section (mm) | ||
Fiber sisal | 50 x 50 | 2500 x 2000 |
GEOFLAM® FX range
Smoke extraction and ventilation | Laying method - glue + .... | Horizontal / Vertical | |
---|---|---|---|
Minimum cross-section (mm) | Minimum cross-section (mm) | ||
Fiber sisal | 50 x 50 | 2500 x 2000 |
Product technical data sheets
GEOTEC® S30 boards
1 hr. fire protective board 30 mm thick and with dimensions from 200 to 1100 (W) x 1000 (L) mm (in steps of 50 mm).
GEOCOL® fireproof glue
Powder-coated glue, available in 25 kg bags, especially formulated for the assembly of GEOTEC® and GEOFLAM® boards.
GEOTEC® A 1/2 Shells
Pre-moulded elements with a length of 1 ml and diameters of 90 or 130 mm (hxW) to protect the threaded rods.
GEOPLÂTRE® N plaster
Specific plaster for finishing work on fire-resistant Geostaff structures, in combination with our prefabricated elements.
GEOTEC® SX30 boards
1 hr. fire protective board, thickness 30 mm and unique dimension 1200 (W) x 1000 (L) mm.
GEOTEC® S45 boards
2-hr. fire protective board 45 mm thick and with dimensions from 200 to 1100 (W) x 1000 (L) mm (in steps of 50 mm).
GEOTEC® A U-plaster
Pre-moulded elements of variable dimensions for the protection of the metal supports of horizontal ducts.
GEOTEC® SX45 boards
2-hr. fire protective board 45 mm thick and unique dimension 1200 (W) x 1000 (L) mm for passive fire protection
Sisal fiber
Vegetable fibre used in the mixture of the "polochonnage" to fill in the joints between the boards.
Product technical
data sheets
Digital tools
Geopro Calculation tool
BIM REVIT
Prescription
documents
Brochures and flyers
Brochure - Cas de montage grande section comprise entre 1001 et 1250 mm - Conduit horizontal GEOTEC
Télécharger plaquetteBrochure - Cas de montage inférieure ou égale à 600mm - Conduit horizontal GEOTEC
Télécharger plaquetteBrochure - Cas de montage jusqu'à 1000 x 1000 mm - Conduit désenfumage - ventilation GEOTEC collé vissé
Télécharger plaquetteBrochure - Cas de montage où largeur intérieure comprise entre 1251 et 2500 mm - Conduit horizontal GEOTEC
Télécharger plaquetteBROCHURE COUPE FEU 4 H GEOTEC S45
Télécharger plaquetteBROCHURE PLANCHER BOIS
Télécharger plaquettePlaquette entreprise A4
Télécharger plaquettePhotos and site returns